Model Number: 317-A001 Key Specifications/Special Features: Display:POL-200 polarimeteris equipped with the 5.6 inch touch screen that used to show measured value, function keys and help messageIn the measurement and setting modes, the instrument will show different user interfacesSetup menu:Semiautomatic polarimeter contains an integrated setup menu that allows you to customize each displayed option to meet measurement requirementsCan use for measuring the 4 parameters, including the optical rotation, specific rotation, concentration and international sugar scale
  • Click the setup icon to enter the setup menu, press measurement mode icon to select desired measurement mode
  • When the setting is completed, the instrument will automatically return to selected measurement mode
  • Receiving the stored data:
    • Connect the USB cable to polarimeter and computer (communication port COM1), click the receive button, the stored data in instrument will automatically send to computer
    • Searching the data:
    • If you would like to search a specific measured value from the database or uploaded data, click the search button, the screen will show a search criteria dialog
    • Available search criteria include the time and sample name
    • After selecting or entering the search criteria, click the ok button, the screen will show all qualified records
    • Print the report: if you would like to print current data, click the print button, the printer will output data sheet
    • Data recall: DAS data acquisition system has a large database used to store the all uploaded data, if you need to view previous data, click the, recall button, the screen will show all data in the database
  • Delete the data:
    • If you need to delete the certain data, click the data field, then click the delete button, once deleted, the data cannot be recovered calibration
    • Semiautomatic polarimeter supports 1 to 3 points calibration, but calibration is not required unless the measured value appeared serious deviation
    • Click the setup icon during the measurement mode, the screen shows the setup menu
    • Click the calibration icon, the instrument enters the calibration mode
    • Follow the displayed guides to select the number of calibration points, press enter key confirm